Tag Archives: 8569B

HPAK 8569A Microwave Spectrum Analyzer: tuning stabilizer/tickler repair

After fixing the display and front panel related issues (attenuator, “0 dB” indicator), the only major defect remaining so far is the tuning stabilizer circuit. Once the span is set to below 100 kHz, it is activated – and sets the unit to zero span, rather than the span selected, permanently. Only when the stabilizer is disabled (there is a button on the front panel), the span is back to normal.

The source of this issue – most likely, the A14 tuning stabilizer assembly. Switched the board (part number 08565-60018) with the identical board of a 8565A – and, as expected, the zero span issue is gone!!

Now, we just need to fix the board.

The description in the service manual is actually pretty clear – the circuit uses a 1 MHz harmonic sampler, to keep the frequency of the LO stable. The initial lock is achieved by setting the analyzer to zero span, finding a frequency close to 1 MHz that represents a lock point. This frequency is controlled by a voltage, and a very long lasting sample-and-hold is used, than employs a special construction of a HP reed relay, and a PE/PTFE(?) lowest leakage capacitor – the white coil in the front, left, and the the capacitor, front, right – in the middle, a PTFE isolated post, going to a FET gate.

8569a a14 assy 08565-60018

Certainly, a very special capacitor. Once this is achieved, error voltage of the sampler is used to steer the LO, and the analyzer is returned from zero to normal span mode.

The sequence of all these steps – controlled by a very interesting chain of transistors, resistors, and capacitors – nowadays, just a few lines of program code… but, nothing better than a handful of discrete high quality components.

The “control generator”, see schematic below – it is not controlling the sequence properly – and, again, a defective cap. 0.1 µF (!), tantalum – red frame; a few 100 Ohms – near short. No way that this can get charged, and let the sequence proceed.
08565-60018 control generator schematic

Replaced it, with a regular 0.1 µF cap (why did they use a tantalum??), and: A14 assy working again. 20 kHz span, 10 kHz resolution bandwidth. Working just fine – at all frequencies up to 20 GHz, the highest I can check here.

8569a working stabilizer 20 khz span 10 khz res bw

The black sheep (date code: 1980, week 7):

8565a a14 culprit

We can’t argue that they didn’t skim on parts – at the time, certainly, one of the best 0.1 µF tantalums available.
Parts list specifies 150D series, MIL–PRF–39003 mil-spec qualified high reliability hermetically sealed cap:

150d tantalum

HPAK 8569A Microwave Spectrum Analyzer: front panel repair/re-build

The easy of use by the three-knob operation mentioned before – it has a downside: a very complex front plate assembly. And this might be the reason why more modern units almost exclusively use single-axis rotary encoders, often only one single encoder to operate all functions, per unit. The multi-turn-coupled-limited-synchronized-geared movements, just too complex and too expensive, too heavy, too laborious to maintain.

The front panel controls – as delivered.
8569a front panel rhs as delivered

The 8569A, 8569B and 8565A all use very similar front assemblies – only seem to differ in the print and in the exact shade of the label colors. And these assemblies use plastic parts – knobs, wheels, and so on. After 30+ years, no wonder, aging has visible effect, and parts become brittle. Common defects are broken-off sliding contacts. Not a big thing, can be fixed (re-attach the contact with M1.2 screws).

The attenuator and “0 dB” warning indicator – these are located on the same rotary cam, same contact pair. And, you bet, the corresponding wiper contact – broken off-missing.

Well, having rebuild some of these assemblies for other repair jobs before – the only way to fix this will be to take the assembly apart, almost fully. Actually, if all screws are kept well-sorted, not really such a big effort as is sounds. Some hours, but then it will be working again.

8569a rebuilding the from assembly

In addition to just the repair, all contacts and surfaces were thoroughly cleaned, by various means: DeOxit D5, a good eraser, isopropyl alcohol. For the painted surfaces and parts, use 40-50% isopropyl alcohol only, and a rather soft or medium-hard brush, to avoid damage to the paintwork.

The replacement cam (on the right) has two wiper contacts, the defective part, only one – the plastic fingers holding it down became brittle, and it eventually broke off.

8569a attenuator selector cam

Here, the result: the rebuild assembly. From earlier repairs, the remaining contacts should last – somehow, no all are susceptible to breaking-off; or it is just the amount of use they get – at least, I have some units fixed with small screws holding down the contacts, and there have since been working better than before. Therefore, I am not too worried about more contacts failing in the near future.

8569a rebuild front panel assy

Note: as it turned out, also the 12 dB vernier attenuator encoder had a partially broken off contact – can be fixed with some epoxy glue, but I rather replaced the encoder, with a spare from the parts unit.

HPAK (HP Agilent Keysight) 8569A Microwave Spectrum Analyzer: a great find, 10 MHz to 22 GHz, and some spare parts at hand

Two weeks ago I spotted something on xbay, a 8569A spectrum analyzer, for parts or repair (“powers up, no display”), at a very reasonable price – just a bit above USD 300. This is not much more than the parts value of the 70 dB attenuator of this unit, so, a great deal in any case. The pictures shows a really beaten-up unit, black dirt all over it (mould?), and corrosion. At least the connectors seemed to have caps on them, fair enough. And it has option 1, a 100 MHz comb generator, good out to 20 GHz.

Unit as offered… doesn’t look very appealing.
8569a offer

Good news: I have a severely damaged 8565A here (broken frame, but still full of good parts), as a donor unit – looks like it is a unit that had been buried under tons of heavy stuff, or had a truck driving over it, a heavy truck. And, it doesn’t have a CRT.

8565a donor unit

The 8565A, 8569A and 8569B analyzers – these have a really easy to use design, three-knob operation, and are the best analyzers, from my point of view, for any general service and adjustment work, at any frequency above a few MHz. With resolution bandwidth down to 100 Hz, also up for some more special tasks. Sure, there are the 8568 and 8566 units (I also own a 8568B), but these are bulky, and you always need to push buttons AND turn knobs – more like for a cal lab or really high precision characterization work.

Plenty more modern analyzers exist, with LCD display, and all kinds of software features. They come at a price, and once you have experienced the responsiveness and easy of operation of the 8569 series, fancy LCD screens and color buttons can’t really be the reason to consider anything else. Good units, fully functional-refurbished, go for about USD 2-3k.
For general-purpose, low budget work – if you are looking for a 20+ GHz analyzer, there isn’t much that goes for less than 10k used, or 30-50k new. Some of the later, semi-portable 856x series might be an alternative. However, these have a rather small screen, just about 3.8″ diagonal, for the spectrum display, while the 8569B has 5.5″, and an electrostatic CRT, of excellent brilliance.
Also, keep in mind that the down-converted output can be easily converted to digital data by SDR, to recover even the most complex modulation schemes. No need to pay extra dollars to get custom plugins for modern analyzers. Such things pay off for the big corporations, but if you are up for special tasks, there is no way around dealing with some software, anyway.

Currently, I use a 8569B in the workshop back in Germany, and here, in the US, I rely on a 8565A – which is essentially the same RF hardware, but has an analog storage display (variable persistence), rather than a digital display, like the 8659B. Also, the 8565A doesn’t have GPIB or other means of data bus, all computer-controlled measurments require the use of a A/D D/A converter unit.
So, it would be good to get the 8569A working, and eventually, sell-off the 8565A.

Historically, it seems the 8565A first appeared in about 1978. Looking up in some old HP catalogs – the 8569A appeared first in the 1982 edition (marked as “new”); quite surprising, because the unit I have here has a much earlier serial (1980) – and also the parts data back to end of 1980.

8569a serial
No doubt, seems to be a rather early unit (take the first two digits of the serial, and add 1960 = year of manufacture).

HP-Cat-1982-8569a

HP-Cat-1983-8569b

In the 1983 edition, HP already has the 8569B, with virtually identical specs. Quite interestingly, the 8565A (with the analog storage display!) remained available, in parallel with the digital-display 8569B, for many years – up until 1988 (at USD 34k, including option 1). The price difference was rather small, just about 10% (about USD 3k) more for the 8569B, with the much better display, and digital/automated control capabilities.

If you study the inner workings of the 856x in detail, it is also evident that a good part of the circuits were taken from 8555A analyzer, introduced in about 1970….

After all this, the analyzer arrived – well packaged. And first downside of it, it is 30 kg, 65 pounds, plus packaging. But hey, who needs to carry spectrum analyzers of this kind around – it will rest on the microwave test bench, along with generators, counters and so on, some 100s of pounds anyway.

Well, plugged it in – the display is really dead, but the frequency display is on. Powder supply is good. And, the X-Y output – when connected to a scope – you can actually get some signals, and it is sweeping. There is hope.

After some probing and basic tests, these are the items found so far:

(1) No display. However, there is a display signal on the deflection plates, and it is looking sound, so the digital display generator seems to work just fine. Just the CRT isn’t. Might be hard to fix, if the CRT is at fault – I can’t see the cathode glowing….

(2) The attenuator at 60-70 dB, and “0 dB” attenuator light at the front panel – not working (missing 20 dB attenuation; light off even when attenuation is set to 0 dB.

(3) Mechanical defect of the span knob – general mechanical soundness of the front panel. Will need very through cleaning, aligment, etc.

(4) Something is wrong with the tuning stabilizer, engaged at below 100 kHz span – when it is activated, it sets the span to zero, and never comes back, unless the stabilizer is de-activated.